INPUT
|
Voltage
|
90-264VAC universal full range
|
Frequency
|
47-63Hz
|
Current
|
<0.2A@100V AC input, full load condition
|
Inrush Current
|
<40A@115V , <60A@230V AC input.Cold start at 25℃ ambient
|
Leakage Current
|
<0.2A@ 264V AC input
|
OUTPUT
|
PART NO.
|
AD05WD03
|
AD05WD05
|
AD05WD07
|
AD05WD09
|
AD05WD12
|
AD05WD15
|
AD05WD18
|
AD05WD24
|
Voltage
|
3V
|
5V
|
7V
|
9V
|
12V
|
15V
|
18V
|
24V
|
Max Load
|
0-2A
|
0-1.2A
|
0-0.8A
|
0-0.6A
|
0-0.5A
|
0-0.4A
|
0-0.3A
|
0-0.25A
|
Output Tolerance
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
Ripple Noise(MAX)
|
50mV
|
50mV
|
70mV
|
90mV
|
120mV
|
150mV
|
180mV
|
240mV
|
Efficiency(MIN)
|
≥65%
|
≥65%
|
≥65%
|
≥75%
|
≥75%
|
≥75%
|
≥75%
|
≥75%
|
Output MAX
|
5W
|
5W
|
5W
|
5W
|
5W
|
5W
|
5W
|
5W
|
PROTECTION
|
Over Voltage
|
over 120%~150 max
|
Shutdown and latch off, recover after re-start up
|
Over Load &
Short Circuit
|
When power supply over 105%~150 max load or short circuit acted,powr supply will be shutdown and recover automatically after the fault is removed
|
Over Temperature
|
Over 95℃,the power supply will shutdown.
|
ENIRONMENT
|
Temperature
|
Operating:-20~70℃;De-rating:45~70℃:2.5%/℃;Storage:-40~+85℃
|
Humidity
|
Operating: 20%~90% RH(non condensing);Storage:10%~95% RH(non condensing)
|
SAFETY
|
Withstand voltage
|
I/P-O/P:3KVAC,I/P-PE:1.5KVAC,O/P-PE:0.5KVAC,1 minute
|
Isolation resistance
|
I/P-O/P,I/P-FG,O/P-FG>100MΩ/500VDC at 25℃/70% RH
|
Safety standard
|
UL 60950-1 2nd,CSA C22.2 No.60950-1-07 2nd,TU EN 60950-1:2006,
IEC 60950-1:25005,standard, EN61558, EN60335, EN60065
|
EMC
|
EMI
|
EN 55022 CLASS B、FCC CFR 47 PART 15 CLASS B、CNS 13438 CLASS B
|
Compliance to EN61000-3-2 CLASS D,EN61000-3-3
|
EMS
|
EN55024:EN61000-4-2,3,4,5,6,8,11
|
OTHERS
|
Cooling
|
Natural Cooling
|
M.T.B.F.
|
100K hours
|
Dimension
|
56x50x18mm ( L*W*H )K-059-CABLE
|
Packing
|
N.W.:70g/1pc; 15pcs/1.05kg CUFT/1 CTN
|